تفاصيل
الجهات المعتمدة
المواد / المنتجات المختبرة الاختبار المواصفات القياسية / التقنيات المستخدمة وصف المعدات المستخدمة

PV Module

Read More
4.1 (MQT01): Visual inspection

IEC 61215-2:2016 § 4.1 IEC 61215-2:2021 § 4.1 SASO IEC 61215-2

Read More
1-Camera 2-Luxmeter 3-Caliper

PV Module

Read More
4.2 (MQT02): Maximum power determination

IEC 61215-2:2016 § 4.2 IEC 61215-2:2021 § 4.2 SASO IEC 61215-2

Read More
1-Radiant source 2-PV reference device 3-Temperature monitoring device 4- I-V curve measuring device

PV Module

Read More
4.3 (MQT 03): Insulation test

IEC 61215-2:2016 § 4.3 IEC 61215-2:2021 § 4.3 SASO IEC 61215-2

Read More
1- D.C. Voltage source 2- Insulation resistance measurement

PV Module

Read More
4.4 (MQT 04): Measurement of temperature coefficients

IEC 61215-2:2016 § 4.4 IEC 61215-2:2021 § 4.4 SASO IEC 61215-2

Read More
1-Radiant source 2-PV reference device 3-Temperature monitoring device 4- I-V curve measuring device

PV Module

Read More
4.5 (MQT 05): Measurement of NMOT

IEC 61215-2:2016 § 4.5 SASO IEC 61215-2

Read More
HALM Solar Simulator

PV Module

Read More
4.6 (MQT 06): Performance at STC

IEC 61215-2:2016 § 4.6 IEC 61215-2:2021 § 4.6 SASO IEC 61215-2

Read More
HALM Solar Simulator

PV Module

Read More
4.7 (MQT 07) : Performance at low irradiance

IEC 61215-2:2016 § 4.7 IEC 61215-2:2021 § 4.7 SASO IEC 61215-2

Read More
HALM

PV Module

Read More
4.8 (MQT 08): Outdoor exposure test

IEC 61215-2:2016 § 4.8 IEC 61215-2:2021 § 4.8 SASO IEC 61215-2

Read More
1-Open rack 2-Solar irradiation monitor 3-Means or mount the module 4-Resistive load

PV Module

Read More
4.9 (MQT 09): Hot-spot endurance test

IEC 61215-2:2016 § 4.9 IEC 61215-2:2021 § 4.9 SASO IEC 61215-2

Read More
1-Radiant source 2-Module I-V curve tracer 3Equipment for current measurement 3-Opaque cover 4- An appropriate temperature detector (IR camera)" 5-Equipment to record irradiance levels

PV Module

Read More
4.10 (MQT 10): UV preconditioning test

IEC 61215-2:2016 § 4.10 IEC 61215-2:2021 § 4.10 SASO IEC 61215-2

Read More
Temperature controlled test chamber Temperature monitoring device Instrumentation for measuring the irradiance Resistive load
Sec
مفعل: صلاحية الاعتماد سارية المفعول.
Sec
منتهي: صلاحية الاعتماد منتهية وفي هذه الحالة يعتبر مسحوب.
Sec
ملغي: تم إلغاء الاعتماد بناء على طلب الجهة أو بناء على قرار من قبل المركز وفي هذه الحالة يعتبر مسحوب.
Sec
معلق: تم تعليق الاعتماد بناء على طلب الجهة أو بناء على قرار من قبل المركز.
ملفات تعريف الإرتباط

هذا الموقع يستخدم ملفات تعريف الارتباط الخاصة للتأكد من سهولة الاستخدام وضمان تحسين تجربتك أثناء التصفح. من خلال الاستمرار في تصفح هذا الموقع، فإنك تقر بقبول استخدام ملفات تعريف الارتباط سياسة الخصوصية