تفاصيل
الجهات المعتمدة
المواد / المنتجات المختبرة الاختبار المواصفات القياسية / التقنيات المستخدمة وصف المعدات المستخدمة

PV Module

Read More
4.1 (MQT01): Visual inspection

IEC 61215-2:2016 § 4.1 IEC 61215-2:2021 § 4.1 SASO IEC 61215-2

Read More
1-Camera 2-Luxmeter 3-Caliper

PV Module

Read More
4.2 (MQT02): Maximum power determination

IEC 61215-2:2016 § 4.2 IEC 61215-2:2021 § 4.2 SASO IEC 61215-2

Read More
1-Radiant source 2-PV reference device 3-Temperature monitoring device 4- I-V curve measuring device

PV Module

Read More
4.3 (MQT 03): Insulation test

IEC 61215-2:2016 § 4.3 IEC 61215-2:2021 § 4.3 SASO IEC 61215-2

Read More
1- D.C. Voltage source 2- Insulation resistance measurement

PV Module

Read More
4.4 (MQT 04): Measurement of temperature coefficients

IEC 61215-2:2016 § 4.4 IEC 61215-2:2021 § 4.4 SASO IEC 61215-2

Read More
1-Radiant source 2-PV reference device 3-Temperature monitoring device 4- I-V curve measuring device

PV Module

Read More
4.5 (MQT 05): Measurement of NMOT

IEC 61215-2:2016 § 4.5 SASO IEC 61215-2

Read More
HALM Solar Simulator

PV Module

Read More
4.6 (MQT 06): Performance at STC

IEC 61215-2:2016 § 4.6 IEC 61215-2:2021 § 4.6 SASO IEC 61215-2

Read More
HALM Solar Simulator

PV Module

Read More
4.7 (MQT 07) : Performance at low irradiance

IEC 61215-2:2016 § 4.7 IEC 61215-2:2021 § 4.7 SASO IEC 61215-2

Read More
HALM

PV Module

Read More
4.8 (MQT 08): Outdoor exposure test

IEC 61215-2:2016 § 4.8 IEC 61215-2:2021 § 4.8 SASO IEC 61215-2

Read More
1-Open rack 2-Solar irradiation monitor 3-Means or mount the module 4-Resistive load

PV Module

Read More
4.9 (MQT 09): Hot-spot endurance test

IEC 61215-2:2016 § 4.9 IEC 61215-2:2021 § 4.9 SASO IEC 61215-2

Read More
1-Radiant source 2-Module I-V curve tracer 3Equipment for current measurement 3-Opaque cover 4- An appropriate temperature detector (IR camera)" 5-Equipment to record irradiance levels

PV Module

Read More
4.10 (MQT 10): UV preconditioning test

IEC 61215-2:2016 § 4.10 IEC 61215-2:2021 § 4.10 SASO IEC 61215-2

Read More
Temperature controlled test chamber Temperature monitoring device Instrumentation for measuring the irradiance Resistive load
Sec
مفعل: صلاحية الاعتماد سارية المفعول.
Sec
منتهي: صلاحية الاعتماد منتهية وفي هذه الحالة يعتبر مسحوب.
Sec
ملغي: تم إلغاء الاعتماد بناء على طلب الجهة أو بناء على قرار من قبل المركز وفي هذه الحالة يعتبر مسحوب.
Sec
معلق: تم تعليق الاعتماد بناء على طلب الجهة أو بناء على قرار من قبل المركز.