Accredited Bodies

Thomas Bell-Wright Saudi Arabia LTD

Active

Certificate number

Certificate number

N-T-00606

Start date

Start date

11/18/2024

End date

End date

11/17/2027

Service type

Service type

Testing Laboratory

Accreditation specification

Accreditation specification

ISO/IEC 17025:2017

Main field

Main field

Construction

Address

Address

Riyadh

Phone

Phone

Notes

Notes

Validity of the accreditation

Tested materials/products
Characteristics of measured quantity / range
Standard specifications / technologies used
Description of equipment used
No data
اسم الاختبار
المنتج / المادة
طريقة العمل / المواصفة
التقنية / الجهاز المستخدم
Reaction to fire - surface burning characteristics BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Reaction to fire ASTM E84-23d Steiner Tunnel
Reaction to fire - surface burning characteristics BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Reaction to fire SASO ASTM E84-19 Steiner Tunnel
Reaction to fire - surface burning characteristics BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Reaction to fire UL 723, 11th Edition, 2023 Steiner Tunnel
Fire resistance (General Requirements) BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Fire resistance BS 476 - 20:1987 (Amd 1:1990, Corr 1:2014) 3x3m Furnace
Fire resistance (General Requirements) BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Fire resistance EN 1363-1:2020 3x3m Furnace
Fire resistance (General Requirements) BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Fire resistance EN 1363-2:1999 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES EN 1634-1:2014+A1 :2018 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES BS 476 - 22:1987:Section 6, 7 and 8 Corr 1:2014 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES UL10B:2020 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES SASO UL10B:2008 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES UL10C 3rd Ed. 2016 (R2021) 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES SASO UL10C : 2008 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES NFPA 252:2022 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES SASO NFPA 252: 2010 3x3m Furnace
Fire resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES UL10D 2nd Ed. 2017 (R2022) 3x3m Furnace
Fire resistance WALLS AND PARTITIONS - Non load bearing EN 1364-1:2015 3x3m Furnace
Fire resistance WALLS AND PARTITIONS - Non load bearing BS 476 - 22:Section 5 :1987 Corr 1 :2014 3x3m Furnace
Fire resistance WALLS AND PARTITIONS - Non load bearing ASTM E119-24 3x3m Furnace
Fire resistance WALLS AND PARTITIONS - Non load bearing SASO ASTM E119-22 3x3m Furnace
Fire resistance WALLS AND PARTITIONS - Non load bearing UL 263 Ed 14:2022 3x3m Furnace
Fire resistance GLAZING & WINDOW ASSEMBLIES UL 9 Ed 8 2020 3x3m Furnace
Fire resistance GLAZING & WINDOW ASSEMBLIES BS 476 - 22:1987:Section 10 Corr 1 :2014 3x3m Furnace
Fire resistance GLAZING & WINDOW ASSEMBLIES NFPA 257:2022 3x3m Furnace
Fire resistance GLAZING & WINDOW ASSEMBLIES SASO-NFPA-257 3x3m Furnace
Fire testing PENETRATION SEALS BS EN 1366-3:2021 3x3m Furnace
Fire resistance PENETRATION SEALS ASTM E814-24 3x3m Furnace
Fire resistance PENETRATION SEALS UL 1479 Ed4:2023 3x3m Furnace
Fire resistance PENETRATION SEALS SASO UL 1479 Ed 4, (May 2021) 3x3m Furnace
Fire resistance LINEAR JOINT SEALS BS EN 1366-4:2021 3x3m Furnace
Fire resistance DAMPERS UL 555 Ed 7:2020 (fire test only) 3x3m Furnace
Fire resistance DAMPERS SASO UL 555: 2008 (Fire Test Only) 3x3m Furnace
Integrity of building elements after fire exposure HOSE STREAM APPLICATION ASTM E2226-23a 3x3m Furnace
Fire testing CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS EN 13501-2:2023 3x3m Furnace
Fire testing CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS SASO-GSO-EN-13501-2:2023 3x3m Furnace
Air leakage EXTERIOR WINDOWS, CURTAIN WALLS AND DOORS ASTM E283/E283M-19 Test Chamber, Pressure-measuring apparatus, air system
Air leakage EXTERIOR WINDOWS, CURTAIN WALLS AND DOORS SASO ASTM E283/E283M-2014 Test Chamber, Pressure-measuring apparatus, air system
Structural performance by uniform static air pressure difference (Procedure A) EXTERIOR WINDOWS, DOORS, SKYLIGHTS and CURTAINWALLS ASTM E 330/E330M-14 (2021) Test Chamber, Pressure-measuring apparatus, air system
Water penetration by uniform static air pressure difference EXTERIOR WINDOWS, DOORS, SKYLIGHTS and CURTAIN WALLS ASTM E 331-00(2023) Test chamber, Pressure-measuring apparatus, air system, water spray system
Water penetration using dynamic pressure WINDOWS, CURTAIN WALLS and DOORS AAMA 501.1-17 Test chamber, Pressure-measuring apparatus, air system, water spray system, Wind generating device
Vertical inter-story movements CURTAIN WALLING AAMA 501.7-17 Hydraulic jack, test chamber, displacement measuring system
Static test method for evaluating seismic and wind induced inter-storey drift STOREFRONTS, CURTAIN WALLS and SLOPED GLAZING SYSTEMS AAMA 501.4-18 Hydraulic jack, test chamber, displacement measuring system
Water leakage field check STOREFRONTS, CURTAIN WALLS and SLOPED GLAZING SYSTEMS AAMA 501.2-15 Water spray nozzle with control valve and control gauge
Water penetration by uniform static air pressure difference INSTALLED EXTERIOR WINDOWS, DOORS, SKYLIGHTS and CURTAIN WALLS ASTM E1105-15(2023) Test chamber, Pressure-measuring apparatus, air system, water spray system
Air leakage INSTALLED EXTERIOR WINDOWS, CURTAIN WALLS AND DOORS ASTM E783:02(2018) Test chamber, supply air system, pressure measuring apparatus, air flow metering system
Fire Propagation Exterior Wall Cladding Assemblies NFPA 285 ISMA
Fire Propagation Spandrel Panel ASTM E2874-23 ISMA
Fire Propagation Perimeter Fire Barrier ASTM E2307-25 ISMA
Reaction to Fire - surface burning characteristics BUILDING CONSTRUCTION COMPONENTS AND MATERIALS – Reaction to Fire ASTM E84-24 Steiner Tunnel
Fire Resistance HOSE STREAM APPLICATION ASTM E2226-24 3x3m Furnace
Fire Resistance DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES UL 10B-2024 3x3m Furnace
Active

Active

The accreditation is valid

Expired

Expired

Accreditation has expired and, in this case, it is considered withdrawn

Cancelled

Cancelled

Accreditation has been cancelled based on the body’s request or the center’s decision, and in this case, it is considered withdrawn

Suspended

Suspended

Accreditation has been suspended at the body's request or based on SAAC's decision