Accredited Bodies
Active
Certificate number
N-C-00592
Start date
7/30/2026
End date
7/29/2029
Service type
Calibration Laboratory
Accreditation specification
ISO/IEC 17025:2017
Main field
Time and Frequency Measurements - Mass Measurements - Temperature Measurements - Chemistry Measurements - Mechanical Measurements
Address
Riyadh
Phone

Notes
Validity of the accreditation
Website
المتغيّر/الكمية المقيسة |
المدى |
إمكانية المعايرة والقياس |
وصف مختصر للمعدات والقياسات المستخدمة |
مجال القياس |
||||
|---|---|---|---|---|---|---|---|---|
| Mass measurements F1 and below class weights | 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g |
0.000010 g 0.000010 g 0.000020 g 0.000020 g 0.000030 g 0.000050 g 0.00010 g 0.00010 g |
Standarad Weights and Balance | Mass Measurements | ||||
| Weighing Balances (1 mg to 120 kg) |
1 mg to 200 mg 201 mg to 50 g 51 g to 100 g 101 g to 200 g 201 g to 500 g 501 g to 3000 g 3001 g to 20000 g 20001 g to 30000 g |
0.060 mg 0.060 mg to 0.000080 g 0.000080 g to 0.00010 g 0.00010 g to 0.00020 g 0.00020 g to 0.0060 g 0.0060 g to 0.0080 g 0.0080 g to 0.060 g 0.060 g to 0.080 g |
i) E2 class standard weight ii) F1 class standard weight |
Mass Measurements | ||||
| Micropipette (200 µL to 5000 µL) |
200 µL to 1000 µL 1001 µL to 5000 µL |
8.20 µL 29.10 µL |
Gravimetric Method E2 & F1 class standard weight Semimicro Balance |
Mass Measurements | ||||
| Glass wares (Cylinder Flask Beakers Burettes Pipettes Pycnometers) |
1 mL to 100 mL | 0.0082 mL to 1.79 mL | Gravimetric Method E2 & F1 class standard weight Semimicro Balance Top Loading Balance Plate Form Balance |
Mass Measurements | ||||
| Pneumatic Pressure (Gauges) (0 ~ 35) kg/cm2 |
0 kg/cm2 to 35 kg/cm2 | 0.004 kg/cm2 to 0.288 kg/cm2 | Comparison Method Pneumatic test pump with reference Guage |
Mechanical Measurements | ||||
| Temperature & Humidity | (5)℃ to (60) ℃ (3) % to (95) % |
0.71 ℃ 0.71 % to 1.55 % |
Comparison Method Temperature and Humidity Generator |
Temperature Measurements | ||||
| pH meter | (4 7 & 10) pH |
0.12 pH | Traceable pH buffers sachets | Chemical Measurements | ||||
| Conductivity meter | 1413 µs/cm | 7.2 µs/cm | Traceable Standard Conductivity Solution sachets | Chemical Measurements | ||||
| IR Thermometer | Amb. to 500℃ |
|
|
Temperature Measurements | ||||
| Thermometers (Liquid in Glass, Dial and Digital Thermometer) |
|
|
|
Temperature Measurements | ||||
Thermocouple with indicator (Type K, S & N) RTD with indicator |
|
|
|
Temperature Measurements | ||||
|
|
|
|
Temperature Measurements |
Active
The accreditation is valid
Expired
Accreditation has expired and, in this case, it is considered withdrawn
Cancelled
Accreditation has been cancelled based on the body’s request or the center’s decision, and in this case, it is considered withdrawn
Suspended
Accreditation has been suspended at the body's request or based on SAAC's decision